The ENDEAVOUR series of X-ray Generators has been developed for a wide range of radiographic system.

A multiprocessor system performing, each processor local control and regulation, connected via Controlled Area Network Bus (CANBus) ensures high accuracy and reproducibility of all the radiographic data.

Standard Safeties include special features to optimize the lifetime of the tube such as:
 -  Automatic Calibration adjust in the long term
 -  Thermal computer model of X-ray tube in term of Absolute (kJ) and Relative (%) anode load .

Features includes an Intuitive Graphic Oriented Touch Screen Control Console communicating via CANBus to the power rack.
The Anatomic Program Memory in included in the console as standard feature: don't need and additional console.
The control consol present in Digital Readout all the PRE and POST exposure parameters - PRINTABLE. Printed labels include
 - Radiographic parameters summary
 - Anatomic Program name
 - Technique used
 - Number of exposure for an exam
 - Dose in mGy*cm2
 - User's Input string (for Patient identification p.e.)

Includes also the possibility to control the exposure via Semiconductor or Ionizing chambers and compensate the exposure for particular screen combination and kV response.

link to SPARE PARTS DIRECTORY

MODEL

R306.35 (50 HF R)

R306.36(65 HF R/ RF)

Intermittent Mode Characteristics (Radiography)  

High Voltage Waveform

High Frequency Multi-pulse 

Nominal Voltage  

150 kV  

RX Tube Highest Current  

630 mA

800 mA

Mains Power Output 

50 kW  

65 kW  

Minimum Current - Time product  

0,4 mAs  

Range of Loading Factors

from 40 to 150 kV - 1 kV step

R'10 Scale

10..630mA

R'10 Scale

10..800mA

Exposure Time  

R'10 Scale from 0,001 to 6 s.  with mAs indication

AEC Techniques

1 Point (kV only)

2 Points (kV, mA)

Free Technique

 2 Points (kV,  mAs) 

 3 Point (kV,  mA, s) with pre-mAs indication

Automatic Exposure Control 

Semiconductor Chamber type    -    Ionizing Chamber type

Area Dose Product Meter 

Standard Feature; Ionizing Chamber and Printer as Options

Number of Working Station 

max. 4 (Free Exposure plus 3 Fully Configurable Stations)

Power Line Connection  

Nominal Frequency

50/60 Hz

Nominal Supply Voltage

400 V

three-phase

400 V

three-phase

Maximum Power Absorbed

apparent 75 kVA

active 63 kW

apparent 98 kVA

active 82 kW  

Class I and Type B

(UNI EN 60 601-1)

  Class II b (Dir. 93/42/CEE)   

Continuous Mode Characteristics (Fluoroscopy Option in RF Version only)  

Nominal Supply Voltage

-

From 40 to 120 kV

Tube Highest Current

 

5 mA (120 kV)

Tube Current and Voltage

-

5 mA (120 kV)

Automatic Fluoroscopy

-

Yes

Zero Point Technique

-

Yes

Orthopaedic Fluoroscopy

-

Yes

 The manufacturer reserves  the right to improve or change specifications without notice                                                                                                                                           

STANDARD CONTROL CONSOLE for R-series

MODEL l
in
mm
d
in
mm
h
in
mm
NOTE

C306.36
CONTROL DESK  

Code 953.703

265

185

90

20 m. Connection Cable

96 Anatomic Program

User input program name in 2x12 character lines, printable on the labels

Heat unit Calculator

POWER RACK DIMENSIONS standard layout

MODEL

l
in
mm

d
in
mm

h
in
mm

NOTE

R306.3x

510

380

920

High Voltage Transformer inside cabinet

NOTE:
ODEL S.p.A. reserves the rights to change specifications without notice

Special features

  • III Generation Power Electronics (High Frequency technology)
  • High accuracy and reproducibility also on short exposures
  • Electronic Regulation of High Voltage
  • Electronic Regulation of Filament Lighting
  • Numerical Real Time Regulation of Tube Current
  • Graphic Oriented Service Program for maintenance (ODEL Navigator)